9.5.1 Access to electronic equipment

• Remove the back cover to access the battery
and electronic equipment compartment
3.1.1].
If necessary for access to the components below,
remove the protection (1) secured by four screws
(2).

9.5.2 Replacing the AC-0 control unit

The AC-0 control unit (1) is mounted on a plate (2) and connected to the general electrical system
by means of:
– 5 cables (3) with eyelet ter-
minal corresponding to:
FW
= Traction motor
phase
–BATT = Black - Negative
Battery
+BATT = Red - Battery
positive
FU
= Traction motor
phase
FV
= Traction motor
phase
– 3 connectors (4);
– 1 plug (5) of the cooling fan.
1. Disconnect all connectors mentioned above.
2. Remove the plate (2) fixed by four screws (6).
When mounting, pay attention to the correct repositioning of the connectors and cables and tight-
en the nuts of the cable eye terminals (3) to the value indicated on the control unit itself (5.5-6 Nm).