Wolf Sub-Zero ICB400 Series Service Manual page 97

International wine storage
Table of Contents

Advertisement

TroubleShoot Guide
Wine Storage Error Code Troubleshooting Guide Instructions
Error Codes indicate problems registered by specific components. If error codes are registered, they will appear
before temperature readings while in Diagnostic Mode.
1. Initiate Diagnostic Mode by pressing and holding either COLDER key, and press the POWER key, then release
both keys.
2. Check for Error Codes on the display, making sure to toggle through all possible readings by pressing either
COLDER key or either WARMER key.
3. If Error Codes appear are displayed, follow the Error Code Troubleshooting Guide on next page.
a. The left column of the Error Code Troubleshooting Guide lists the error codes.
b. The right column of the Error Code Troubleshooting Guide explains what tests and/or corrective actions to
perform.
NOTE:
If error codes are observed, the SERVICE indicator will appear constant when Diagnostic Mode ends, indi-
cating error codes are logged. To clear this and the error codes from the software memory, the problem must be
corrected and the unit must be ON. Then, press and hold the bell key for fifteen (15) seconds. The control will emit
a short "beep" when the SERVICE indicator and error codes are cleared.
CODE INDICATION
05
Upper Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
06
Upper Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
07
Lower Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
08
Lower Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
10
Upper Cabinet Warm Temperature alarm
11
Upper Cabinet Cold Temperature alarm
12
Lower Cabinet Warm Temperature alarm
13
Lower Cabinet Cold Temperature alarm
15
Sealed System Fault (evap temperature cannot drop 5° in 5 minutes, 3 consecutive valve activations)
7011544 - Revision A - November, 2008
International W
ine Storage
International W
(See Error Code Table Below)
WINE STORAGE ERROR CODE TABLE
Wine Storage Thermistor Location Codes
MODELS ICB424, ICB427, ICB427R
THERMISTOR LOCATION
Upper Evaporator
Lower Evaporator
Upper Compartment
Lower Compartment
7-6
ine Storage
(ICB400)
(ICB400)
CODE
U U E E
L L E E
U U P P
L L O O
Series