Condenser Removal (Model ICB424)
The condenser is located at the front right of the unit
tray, and is held in place with screws, or rivets passing
up from under the unit tray into the condenser brackets.
To access the condenser, the unit will need to be pulled
from its installation.
NOTE:
If removing a model ICB424 from its installa-
tion, an anti-tip bracket and a countertop bracket may
have been used to make a solid installation.
With unit out of installation
1. Remove access panel from bottom back of unit and
door closer from bottom front corner.
2. Extract screws securing unit tray to cabinet on the
right side, and loosen screws on left side.
3. Separate cabinet from unit tray by leaning cabinet
to the left, then insert a spacer between cabinet and
unit tray (a piece of 2x4 lumber works well).
4. With a tube-cutter, cut inlet tube and outlet tube
approximately 3" from the condenser and lift the
condenser up and out.