Wolf Sub-Zero ICB400 Series Service Manual page 92

International wine storage
Table of Contents

Advertisement

International W
International W
Compressor Access and Removal
(Models ICB427 & ICB427R)
To remove a compressor, the unit tray will need to be
pulled out, then
(See Figure 6-66):
1. Evacuating refrigerant from sealed system.
2. Disconnect compressor electricals.
3. With a tube-cutter, cut suction tube and
discharge tube approximately 35 mm (1-1/2")
from compressor.
4. Extract compressor mounting bolts, and lift com-
pressor off of unit tray.
NOTE:
Sweating the joints apart is not recommended
as this may induce moisture into the sealed system and
could cause a solder restriction in the capillary tube.
Condenser Access and Removal
(Models ICB427 & ICB427R)
To condenser is located at the front right of the unit tray,
and is held in place with screws passing up from under
the unit tray into the condenser brackets. The ICB427R
has a dual condenser with the front of the condenser
being part of the wine storage sealed system and the
back of the condenser being part of the refrigerator
sealed system.
To remove a condenser, the unit tray will need to be
pulled out, then
(See Figure 6-66):
1. Evacuating refrigerant from sealed system.
2. Extract condenser mounting screws.
3. With a tube-cutter, cut inlet and out let tubes
approximately 35 mm (1-1/2") from condenser and
lift condenser off of unit tray.
NOTE:
Sweating the joints apart is not recommended
as this may induce moisture into the sealed system and
could cause a solder restriction in a capillary tube.
ine Storage
ine Storage
(ICB400)
(ICB400)
6-29
Series
Series
Component Access / Removal
Compressor
Figure 6-66. Compressor(s) & Condenser
7011544 - Revision A - November, 2008