TroubleShoot Guide
TROUBLESHOOTING GUIDES
This section of the manual contains:
Temperature Problem Diagnostic Worksheets
Error Code Tables and the Error Code Troubleshooting Guides
General Troubleshooting Guide
Sealed System Diagnostic Tables
Membrane Switch/Ribbon Cable Test Procedures
Temperature Problem Diagnostic Worksheet (does not apply to ICB427R refrigerator section)
The Diagnostic Worksheets on the following three pages are designed to help identify the cause of temperature
problems in a wine storage unit. To fill out the worksheet, familiarity with Diagnostic Mode and Temperature Log
Recall Mode is required (See section 3 of this manual).
NOTE:
Diagnostic Worksheet do not apply to temperature problems in the refrigerator section of a ICB427R.
Follow the steps below and fill out a diagnostic worksheet before referencing the General Troubleshooting Guide.
1.
Write down temperatures shown on display.
a. If unit is OFF, switch unit ON and go to step #2 below.
b. If unit will not run, but display is functioning, go to step #3 below.
NOTE:
"EE" displayed in place of either compartment temperature indicates a compartment thermistor
error. Thermistor errors cause power to the compressor and fans to be cut.
c. If unit will not run and display will not operate, go directly to General Troubleshooting Guide.
2.
Write down the set-points, keeping in mind that the initial key stroke will change the true set-point by a one
degree increment or decrement, depending on choice of WARMER, or COLDER key, respectively.
3.
Initiate Diagnostic Mode by pressing and holding either
COLDER key and the POWER key, then write down any
Error codes that may appear and the temperature read-
ings for each thermistor location. (See Thermistor
Location Code Table at right.)
a. If error codes appear, go directly to
Troubleshooting Guide.
b. If "EE" is displayed in place of temperature, this indi-
cates a thermistor error in that location.
4.
Initiate Temperature Log Recall Mode by pressing and
holding the desired compartment WARMER key and the
POWER key, then toggle through the indexes, writing down the temperature of each index for both compart-
ments. If the "BELL ON" or "SERVICE" indicators light up during an index, circle it on
the worksheet.
a. By observing the temperatures logged, it will be possible to see if any warming or cooling trends
occurred, whether this trend was in one or both compartments, and if there was a power interruption
("BELL ON" illuminate), or that the unit was switched OFF ("SERVICE" illuminates).
b. If double dashes ( - - ) are displayed, the control board is defective.
NOTE:
To see the index/time correlation, refer to the Temperature Log Index Chart on last page of sec-
tion 3 of this manual.
5.
Use the information gathered on the worksheet in conjunction with the General Troubleshooting Guide.
7011544 - Revision A - November, 2008
International W
ine Storage
International W
ine Storage
(does not apply to ICB427R refrigerator section)
(Wine storage and ICB427R Refrigerator Section)
Error Code
7-2
Series
Series
(ICB400)
(ICB400)
Wine Storage Thermistor Location Codes
MODELS ICB424, ICB427, ICB427R
THERMISTOR LOCATION
Upper Evaporator
Lower Evaporator
Upper Compartment
Lower Compartment
CODE
U U E E
L L E E
U U P P
L L O O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents