Wolf Sub-Zero ICB400 Series Service Manual page 28

International wine storage
Table of Contents

Advertisement

International W
International W
Thermistor Malfunction Error Indicators
The diagrams below illustrating what a customer may see on the display if there is a thermistor fault, such as a short
or open condition
(See Figures 3-25, 3-26,
be cut, and error codes to be logged (covered later in this section). If the temperature alarm feature has been
enabled by pressing the bell key on the control panel, the BELL ON indicator will also flash, and the audible alarm
will beep.
NOTE:
Correcting/repairing the thermistor problem will clear the Thermistor Malfunction Error Indicator.
Figure 3-25. EE" at Right and "SERVICE" Flashing = Upper Compartment Thermistor (or its Wiring) Fault
(NOTE: Alarm will Beep and BELL ON will also Flash if Alarm is Enabled)
Figure 3-26. EE" at Left and "SERVICE" Flashing = Lower Compartment Thermistor (or its Wiring) Fault
(NOTE: Alarm will Beep and BELL ON will also Flash if Alarm is Enabled)
Figure 3-27. "SERVICE" Alone Flashing = An Evaporator Thermistor (or its Wiring) Fault
(NOTE: Alarm will Beep and BELL ON will also Flash if Alarm is Enabled)
ine Storage
ine Storage
(ICB400)
(ICB400)
3-27). A thermistor fault will cause power to the compressor and fans to
3-15
Series
Series
Electronic Control System
7011544 - Revision A - November, 2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents