International W
Capillary Tube
(Figure 4-10)
As the warm liquid refrigerant travels through the capil-
lary tube the pressure drops, cooling the liquid before it
enters the evaporator.
Evaporator
(Figure 4-11)
The low pressure/cooled liquid refrigerant travels
through the evaporator absorbing heat from the com-
partment, gradually converting it to a cool gas. This
cool gas then enters the suction line.
Suction Line & Heat Exchanger
The cool gas travels through the suction line which is
soldered to the capillary tube. (These two tubes sol-
dered together create the heat exchanger.) As this cool
refrigerant gas travels through the suction line it
absorbs heat from the warm liquid refrigerant traveling
through the capillary tube. The lukewarm refrigerant
gas then returns to the compressor where the process
begins again.
ine Storage
ine Storage
(ICB400)
(Figure 4-12)
4-7
Series
Series
(ICB400)
CAPILLARY TUBE
COMPRESSOR
Figure 4-10. Capillary Tube
CAPILLARY TUBE
COMPRESSOR
Figure 4-11. Evaporator
CAPILLARY TUBE
HEAT
EXCHANGER
SUCTION LINE
COMPRESSOR
Figure 4-12. Suction Line & Heat Exchanger