Component Access / Removal
Refrigerator High-Side Filter-Drier Removal
(Model ICB427R Only)
To remove the high-side filter-drier it may help to slide
the unit tray out slightly, then
1. Evacuating refrigerant from sealed system.
2. With a tube-cutter, cut filter-drier inlet.
5. At filter drier outlet, use a file to score a line around
the capillary tubes, 25 mm (1'') or less from the out-
let, then fatigue the capillary tube at this line until
they separates.
NOTE:
After capillary tube separates, check tubing for
internal burrs. If burrs exist, repeat step above.
NOTE:
Sweating the joints apart is not recommended
as this may induce moisture into the sealed system and
could cause a solder restriction in the capillary tube.
NOTE:
Check the end of the remaining capillary tube
for internal burrs. If burrs exist, rescore a line around
the capillary tube approximately one inch from the end
and fatigue the capillary tube at this new line until
it separates.
NOTE:
When installing the replacement filter-drier,
insert the capillary tube until it touches the screen, then
pull the capillary tube approximately 9.5 mm (3/8")
away from the screen before brazing
When installing a new filter-drier, be sure to thoroughly
clean the tubing before brazing.
7011544 - Revision A - November, 2008
International W
International W
(See Figure 6-64):
(See Figure 6-65).
ine Storage
ine Storage
(ICB400)
(ICB400)
Figure 6-64. Filter-Drier Removal
Screen inside
Filter-Drier
Capillary Tube
Figure 6-65. Filter-Drier Cut-Away View
6-28
Series
Series
Cut 25 mm (1")
from drier
Score a line 25 mm (1") from drier
9.5 mm
3/8"
(3/8")