International W
Door Adjustment (ICB424, ICB424FS)
NOTE:
Unit must be level before adjusting door.
NOTE:
If ICB424FS door needs adjusting, stainless
steel wrap must be removed to adjust top cabinet hinge
(See Figure 2-9).
If unit is properly installed, blocked and leveled, it may
still be necessary to adjust door left to right and/or in
and out. Adjustments are performed at top and/or bot-
tom cabinet hinge(s)
(See Figure 2-10).
1. Working on only one hinge at a time (top or bottom),
remove and discard the two small Phillips head ship-
ping screws from the cabinet hinge before attempt-
ing adjustments.
2. Using a 1/8" Allen-wrench, loosen and "re-snug" cab-
inet hinge screws, allowing door adjustment.
3. Adjust door as required.
4. After adjusting door, tighten cabinet hinge screws
and check for proper door seal.
Door and/or Drawer Adjustment (ICB427 & ICB427R)
NOTE:
Door and/or drawers on models ICB427 &
ICB427R are non-adjustable. Instead, door and/or
drawer panels must be adjusted if there is alignment
problems. Refer to Installation Manual.
NOTE:
Unit must be level before adjusting door and/or
drawer panels.
ine Storage
ine Storage
(ICB400)
(ICB400)
1. Remove
back brackets.
Remove shipping
screws.
Loosen and re-snug
cabinet hinge
screws.
Figure 2-10. Door / Top Cabinet Hinge Adjustment
2-5
Series
Series
Installation Information
Figure 2-9. Wrap Removal
Cabinet Hinge
7011544 - Revision A - November, 2008
2. Slide
wrap
forward
& lift up