Electronic Control System
Temperature Log Event Indicators
The diagrams below illustrate possible event indicators that may be observed while in Temperature Log Recall
Mode.
(Also see Temperature Log Index Chart
Figure 3-82. "bl" Indicates Index is "blank" - No Temperature has Been Logged Yet
(Only possible within first 14 days of unit operation, or after new control board is installed during service)
SERVICE
Figure 3-83. SERVICE Illuminates - Indicates Unit was switched OFF During that Index Period by Pressing
Figure 3-84. Bell Illuminates - Indicates Power Failure / Interruption During that Index Period
NOTE:
If the unit was in Showroom Mode during any of the 168 indexes, average temperatures will continue to be
logged. No event indicator will appear with these temperatures.
NOTE:
If the unit was switched OFF by pressing the POWER key during any of the 168 indexes and there was still
power supplied to the control board, the average temperatures will continue to be logged. This means temperatures
would be expected to rise and the SERVICE icon would be present in all indexes in which the unit
was OFF.
NOTE:
Temperature Log Recall Mode will end twenty (20) seconds after the last key stroke.
7011544 - Revision A - November, 2008
International W
ine Storage
International W
ine Storage
on next page)
the POWER Key
3-38
Series
Series