Attach the wall plate to the junction box using two 6-32 oval head screws.
7
Note that these screws are provided with the ATX; they are not included
in the bag with the wall plate.
Figure 3-12
Attaching the Wall Plate and Connecting the 10' (3.1 m) Cable
Connect one end of the 10' (3.1 m) non-plenum straight-through cable to
8
the wall plate, and connect the other end to the Primary codec.
Connect a microphone ball to each drop cable.
9
Ensure that the microphone balls are located approximately 7' (213.3 cm)
above the floor. If the ceiling is 10' (304.8 cm) or higher, the microphone balls
are typically too high. In such cases, you must use an optional 6' (182.8 cm)
drop cable (part number 2457-26765-072 for white or 2457-26764-072 for
black) for each Ceiling Microphone Array.