Kyocera Ci1000 Operating Instructions Manual page 126

Final draft august 6, 1998
Hide thumbs Also See for Ci1000:
Table of Contents

Advertisement

6
6-26 Setup from the Control Panel and WebSetup
The Ci1000 can accept jobs via TCP/IP (over either Ethernet or Token Ring),
AppleTalk, and IPX/SPX simultaneously. To configure the Ci1000, choose each
protocol and enter the settings for that protocol.
Enable Ethernet or, if you have enabled and installed the Token Ring option,
enable Token Ring. If your network uses a gateway, enter the gateway address.
—Enable this option if you have a TCP/IP network connected
Enable on Ethernet
to the Ci1000 over Ethernet cabling.
You must enable TCP/IP for Ethernet to use the Fiery WebTools over Ethernet.
—Enter the Ci1000 IP address for Ethernet. The Ci1000 is shipped
IP Address
with the IP address set to the loopback address (127.0.0.1), which is an internal
address used for network checking. If you plan to print with TCP/IP, you must
first assign the Ci1000 a unique network IP address. For information about
setting up printing with TCP/IP, see the Setup Manual or Operating Instructions.
— If you need to set the subnet mask, enter one of the
Subnet Mask(Ethernet)
following values:
• 255.0.0.0 if the IP address starts with a number less than 128
• 255.255.0.0 if the IP address starts with a number from 128 through 191
• 255.255.255.0 if the IP address starts with a number greater than 191
Be sure to confirm the subnet mask setting with your network administrator
before proceeding. In some cases the required setting may be different from those
listed.
—Enable this option if you have a TCP/IP network
Enable on Token Ring
connected to the Ci1000 over Token Ring. If you use Token Ring, enabling TCP/
IP for Token Ring is required for enabling the Fiery WebTools.

Advertisement

Table of Contents
loading

Table of Contents