9
SCANS

■ Scan set mode

Scan set mode is used for programming scanning
speed and scan resume condition.
• Scan speed
The transceiver has 2 speeds for scanning, high and
low.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [(F-5)SCAN] to select the scan screen.
AGC
AGC
MID
MID
VOX
VOX
OFF
OFF
∂ F   S p a n
S p a n            
COMP
COMP
P r o g r a m m e d   P 1 :
P r o g r a m m e d
OFF
OFF
s c a n   e d g e s
s c a n
WIDE
WIDE
PROG
PROG
F
e Push [(F-5)SET] to select the scan set mode
screen.
r Push [(F-1)Y Y ] to select the scan speed item.
AGC
AGC
MID
MID
S C A N S p e e d
S CA N S p ee d
S C A N R e s u m e
S CA N R e su me
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
WIDE
WIDE
é
è
t Rotate the tuning dial to select the scan speed.
• Push [(F-3)DEF] to select the default condition.
y Push [EXIT/SET] to exit the scan set mode.

■ Tone scan

The transceiver can detect the subaudible tone fre-
quency in a received signal. By monitoring a signal
that is being transmitted on a repeater input fre-
quency, you can determine the tone frequency re-
quired to access the repeater.
q Set the desired frequency or memory channel to
be checked for a tone frequency.
w Push [AM/FM] several times to select FM mode.
e Push [TONE] for 1 sec. to enter the tone fre-
quency screen.
AGC
AGC
FAST
FAST
REPEATER TONE
REPEATER TONE
VOX
VOX
OFF
OFF
T-SQL TONE
T-SQL TONE
TONE
TONE
OFF
OFF
é
è
r Push [(F-1)Y Y ] or [(F-2)Z Z ] to check the repeater
tone frequency or tone squelch frequency, respec-
tively. (pgs. 52, 53)
87
SCAN
SCAN
            :     ±    
    ±     1 0 k H z
1 0 k H z
P 1 :    
    0 . 5 0 0 . 0 0 M H z
0 . 5 0 0 . 0 0 M H z
e d g e s   P 2 :
P 2 :   2 9 . 9 9 9 . 9 9 M H z
2 9 . 9 9 9 . 9 9 M H z
F SPAN
F SPAN
FINE
FINE
SET
SET
SCAN SET
H I G H
H I GH
O N
O N
DEF
TONE FREQUENCY
TONE FREQUENCY
88.5Hz
88.5Hz
88.5Hz
88.5Hz
T-SCAN
T-SCAN
DEF
DEF
• Scan resume condition
This item sets the scan resume function ON or OFF.
ON: scan resumes 10 sec. after stopping on a signal
(or 1 sec. after a signal disappears); OFF: scan does
not resume after stopping on a signal.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [(F-5)SCAN] to select the scan screen.
e Push [(F-5)SET] to select the scan set mode
screen.
r Push [(F-2)Z Z ] to select the scan resume condition
item.
AGC
SC AN Sp eed
S C A N S p e e d
MID
S C A N R e s u m e
SC AN Re sum e
VOX
OFF
COMP
COMP
OFF
OFF
WIDE
WIDE
é
è
DEF
t Rotate the tuning dial to turn the scan resume
function ON or OFF.
• Push [(F-3)DEF] to select the default condition.
y Push [EXIT/SET] to exit the scan set mode.
t Push [(F-5)T-SCAN] to start the tone scan.
• "SCAN" flashes while scanning.
TONE FREQUENCY
TONE FREQUENCY
AGC
FAST
FAST
REPEATER TONE
REPEATER TONE
VOX
OFF
T-SQL TONE
T-SQL TONE
TONE
TONE
y When the tone frequency is detected, the tone
scan pauses.
• The tone frequency is set temporarily on a memory
channel. Program into the memory channel to store the
tone frequency permanently.
• The decoded tone frequency is used for the repeater
tone frequency or tone squelch frequency.
u To stop the scan, push [(F-5)T-SCAN].
i Push [EXIT/SET] to exit the tone frequency
screen.
S CA N SET
H IGH
H I G H
O N
O N
188.8Hz
188.8Hz
SCAN
SCAN
88.5Hz
88.5Hz
T-SCAN
T-SCAN

Hide quick links: