Dualwatch Operation - Icom IC-756PROIII Instruction Manual

Hf/50 mhz all mode transceiver
Hide thumbs Also See for IC-756PROIII:
Table of Contents

Advertisement

5
FUNCTION FOR RECEIVE

■ Dualwatch operation

Dualwatch monitors 2 frequencies with the same mode
simultaneously.
During dualwatch, both frequencies should be on the
same band, because the bandpass filter in the RF cir-
cuit is selected for the main readout frequency.
[BAL]
[DUALWATCH]
RIT function can be used for the main readout only.
∂TX function can be used for the transmit readout
(main readout when the split function is OFF; sub
readout when the split function is ON).
• Scanning during dualwatch
Scanning operates only for the main readout. To op-
erate the scan during dualwatch, scan on the main
readout and use the sub readout for your QSO using
both dualwatch and split frequency operation.
q Program the desired programmed scan edges in
the same amateur band. See p. 79 for program-
ming.
• If you plan to operate a ∂F scan, programming the
scan edges may not be necessary.
w Push [SPLIT] to turn the split frequency function
ON.
• "
" appears.
SPLIT
SPLIT
ANT
ANT
2.4k
2.4k
BW
BW
1
VFO
VFO
wq.wop.pp
METER
METER
Po
Po
1
SPLIT
S P L I T
P.AMP
P.AMP
1
T X
TX
VFO
VFO
qr.wpt.pp
ATT
ATT
OFF
OFF
1
e Select VFO mode for the main readout.
r Set the desired operating frequency for the main
readout.
t Push [DUALWATCH] for 1 sec.
• The main and sub readout frequencies are equalized
and the dualwatch function is turned ON.
63
[CHANGE]
[SPLIT]
qw:pp
0
SFT
SFT
12:00
U S B
U S B
FIL2
FIL2
14.100.00
14.100.00
USB
USB
USB
USB
FIL2
FIL2
USB
USB
14.100.00
14.100.00
q Set a desired frequency.
w Push [DUALWATCH] for 1 sec.
• Equalized receive frequency and "
the LCD. This quick dualwatch function can be turned
OFF in set mode. (p. 100)
• Pushing [DUALWATCH] momentarily activates the du-
alwatch with the previously operated frequency.
ANT
ANT
2.4k
2.4k
BW
BW
SFT
SFT
0
1
T X
TX
VFO
VFO
U S B
U S B
wq.wop.pp
METER
METER
Po
Po
14.100.00
14.100.00
1
DUAL-W
D U A L - W
P.AMP
P.AMP
1
56
56
USB
USB
wq.wop.pp
ATT
ATT
OFF
OFF
VFO
V F O
14.100.00
14.100.00
e Set another desired frequency using the tuning dial.
r Adjust [BAL] to set a suitable signal strength bal-
ance between the main and sub readout frequen-
cies.
• S-meter shows the combined signal strength.
t To transmit on the sub readout frequency, push
[CHANGE] or [SPLIT].
ANT
ANT
BW
BW
2.4k
2.4k
SFT
SFT
0
1
VFO
VFO
U S B
U S B
wq.wop.pp
METER
METER
Po
Po
1
14.100.00
14.100.00
SPLIT
S P L I T
D U A L - W
DUAL-W
P.AMP
P.AMP
1
TX
T X
VFO
VFO
USB
USB
wq.wop.pp
ATT
ATT
OFF
OFF
1
14.100.00
14.100.00
y Push [(F-5)SCAN] to select the scan screen.
• Push [EXIT/SET] several times to close a multi-func-
tion screen, if necessary.
u Push [(F-1)PROG] or [(F-2)∂ ∂ F] to start the pro-
grammed scan or ∂F scan, respectively.
• Scan activates on the main readout between the pro-
grammed scan edges or within the ∂F span.
• Transmitting on the sub readout stops the scan.
ANT
ANT
BW
BW
2.4k
2.4k
0
SFT
SFT
1
VFO
VFO
U S B
U S B
wq.wtp.pp
METER
METER
Po
Po
1
14.100.00
14.100.00
SPLIT
S P L I T
D U A L - W
DUAL-W
P.AMP
P.AMP
1
TX
T X
VFO
VFO
USB
USB
wq.wop.pp
ATT
ATT
OFF
OFF
14.100.00
14.100.00
1
AGC
AGC
MID
MID
P R O G R A M S C A N
P R O G R A M S C A N
VOX
VOX
OFF
OFF
∂ F   S p a n
S p a n            
            :     ±    
COMP
COMP
P r o g r a m m e d   P 1 :
P r o g r a m m e d
P 1 :   2 1 . 0 0 0 . 0 0 M H z
OFF
OFF
s c a n
s c a n   e d g e s
e d g e s   P 2 :
P 2 :   2 1 . 4 5 0 . 0 0 M H z
WIDE
WIDE
PROG
PROG
F
FINE
FINE
i To cancel the scan, push [EXIT/SET].
" appear in
DUAL-W
DUAL-W
qw:pp
12:00
FIL2
FIL2
USB
USB
FIL2
FIL2
USB
USB
qw:pp
qw:pp
FIL2
FIL2
USB
USB
FIL2
FIL2
USB
USB
qw:pp
12:00
FIL2
FIL2
USB
USB
FIL2
FIL2
USB
USB
SCAN
SCAN
    ±     1 0 k H z
1 0 k H z
2 1 . 0 0 0 . 0 0 M H z
2 1 . 4 5 0 . 0 0 M H z
F SPAN
F SPAN
SET
SET

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents