■ Remote jack (CI-V) information
D CI-V connection example
The transceiver can be connected through an optional
CT-17
-
CI
V LEVEL CONVERTER
equipped with an RS-232C port. The Icom Communi-
cation interface-V (CI-V) controls the following func-
tions of the transceiver.
Up to four Icom CI-V transceivers or receivers can be
connected to a personal computer equipped with an
RS-232C port. See p. 136 for setting the CI-V condi-
tion using the miscellaneous (others) set mode.

D Data format

The CI-V system can be operated using the following
data formats. Data formats differ according to com-
mand numbers. A data area is added for some com-
mands.
CONTROLLER TO IC-7000
FE FE
70
FE FE E0
IC-7000 TO CONTROLLER
D Command table
Command
Sub command
00
01
Same as
command 06
02
03
04
05
06
00
01
02
03
04
05
07
08
07
00
01
A0
to a personal computer
E0 Cn Sc
Data area
70
Cn Sc
Data area
Description
Send frequency data
Send mode data
Read band edge frequencies
Read operating frequency
Read operating mode
Set operating frequency
Select LSB
Select USB
Select AM
Select CW
Select RTTY
Select FM
Select CW-R
Select RTTY-R
Select VFO mode
Select VFO A
Select VFO B
Equalize VFO A and VFO B
CONTROL COMMAND
mini-plug cable
IC-7000
OK MESSAGE TO CONTROLLER
FD
FE FE
FD
FE FE
NG MESSAGE TO CONTROLLER
Command
Sub command
07
B0
08
0001–0105*
0106, 0107
A0
09
0A
0B
0C
0D
0E
00
01
02
22
23
17
9–15 V DC
Personal
computer
70
E0 FB FD
70
E0 FA FD
Description
Exchange VFO A and VFO B
Select memory mode
Select memory channel
*P1=0100, P2=0101
Select the call channel
(C1=0106, C2=0107)
Set the bank number
(1=A, 2=B, 3=C, 4=D, 5=E)
Memory write
Memory to VFO
Memory clear
Read offset frequency
Set offset frequency
Scan stop
Programmed/memory scan start
Programmed scan start
Memory scan start
Select memory scan start
16
17
142