Router Specifications
Table A-3
DC Electrical Specifications
Description
Input current rating
Source DC service requirement
1. For each PEM.
Caution
Table A-4
Environmental Specifications
Description
Temperature
Humidity
Altitude
Heat dissipation
Acoustic noise
Shock
Vibration
1. G is a value of acceleration, where 1G equals 32.17 ft/sec
2. Grms is the root mean square value of acceleration.
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
A-4
Value
60A maximum @ 40.5 VDC
Sufficient to supply the rated input current. Local codes apply.
To ensure that the chassis configuration complies with the required power
budgets, use the on-line power calculator. Failure to properly verify the
configuration may result in an unpredictable state if one of the power units fails.
Contact your local sales representative for assistance.
Value
Operating: 32° to 104°F (0° to 40°C)
Nonoperating: –4° to 149°F (–20° to 65°C)
Operating: 10 to 90% noncondensing
Nonoperating: 5 to 95% noncondensing
Operating: 0 to 10,000 ft (0 to 3,000 m)
Nonoperating: 0 to 15,000 ft (0 to 4,570 m)
11,602 BTU/hr maximum (original series)
16,378 BTU/hr maximum (enhanced series)
70 dBa maximum
Operating (halfsine): 21 in./sec (0.53 m/sec)
Nonoperating (trapezoidal pulse): 20G
Operating: 0.35 Grms
Nonoperating: 1.0 Grms from 3 to 500 Hz
Appendix A
1
, 52 in./sec (1.32 m/sec)
2
from 3 to 500 Hz
2
2
(9.81 m/sec
).