4-2-2

Selecting the Discrimination Outputs (oUt)

There are three methods to discriminate and output measure-
ment data. Select the best method for the application.
HIGH threshold
LOW threshold
Discrimina-
tion output
HIGH/LOW
output mode
Indicator
Discrimina-
tion output
PASS/NG
output mode
Indicator
Discrimina-
tion output
HIGH/LOW
inverted out-
put mode
Indicator
Procedure
1 HIGH/LOW Output Mode (h l1)
Measured value x HIGH threshold: HIGH output ON
Measured value y LOW threshold: LOW output ON
2 PASS/NG Output Mode (pass)
LOW threshold < Measured value < HIGH threshold:
PASS output ON
Measured value x LOW threshold or
Measured value y HIGH threshold:
NG output ON
3 HIGH/LOW Inverted Output Mode (h l2)
Measured value y HIGH threshold: HIGH output ON
Measured value x LOW threshold: LOW output ON
1 Set the operating mode selector to RUN.
2 Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.
Section
4-2
Measured value
ON
OFF
39