Setting Thresholds
3-2-3
Forced-zero Setting
To set the thresholds, a measured value based on a reference
workpiece is first set as zero. A tolerance is then added to and
subtracted from the reference value (zero) to set the results as
HIGH and LOW thresholds. Forced-zero settings are possible
only if the unit is set to mm.
The HIGH and LOW thresholds are kept on hold when the refer-
ence workpiece is changed, which enables easy changeovers.
Thresholds are displayed between –9.999 and F.S. (see note),
but the linear output voltage will not change.
Note
Display Unit Selection
Reference Value Setting
1 "F.S." stands for full scale. In the case of the Z4LB-S10V2,
for example, the F.S. value is 10 mm.
2 Forced-zero Indicator
When the forced-zero settings are enabled, the forced-zero
indicator will turn ON.
Forced zero is set.
3 s
SET
05.697
00.000.
HIGH indicator
Display
LOW indicator
1 Set the measurement unit selector to mm.
2 Set the operating mode selector to RUN.
3 Set the workpiece and press the SET Key for 3 s.
The forced-zero indicator will turn ON, when the measured
value will be set as the reference value (0).
The forced-zero in-
dicator will turn ON.
Forced-zero indicator