Omron Z4LB V2 Instruction Manual page 64

Parallel beam linear sensor
Table of Contents

Advertisement

Key Settings
PASS/NG Output Mode
HIGH threshold
Measured value
LOW threshold
PASS output
NG output
HIGH/LOW Inverted OUTPUT Mode
HIGH threshold
Measured value
LOW threshold
HIGH output
LOW output
Procedure
scale
Measurement
width
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 Set the operating mode selector to RUN.
2 Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.
3 Press the Up Key to go to the hysteresis setting.
Discrimination
outputs
4 Press the SET Key.
The hysteresis can now be set.
5 Press the Right Key to move the cursor the digit to be
changed and press the Up Key to set the hysteresis.
Hysteresis
Hysteresis
oUt
Hysteresis
setting
Section
4-2
hys
41