Setting Thresholds
The selected value flashes.
LOW Threshold Setting
Teaching value of reference workpiece
30
3 Press the Right Key to move the cursor to the value to be
changed.
The cursor will shift to the right by one digit whenever the
Key is pressed.
4 Press the Up Key and change the value.
The value will increase by 1 whenever the Key is pressed.
02.746
Press the Up Key.
02.846
Press the Up Key.
02.946
5 Press the SET Key.
The value will be entered and the indicator will flash twice.
6 Set the operating mode selector to L.
The LOW indicator will flash and the display will show the
present LOW threshold.
7 Take steps similar to 2 and 5 to set the LOW threshold.
The teaching value minus an approximate value of 0.7% FS
will be displayed as the LOW threshold.
LOW threshold
02.746
Press the Right Key.
02.746
Press the Right Key.
02.746