Omron Z4LB V2 Instruction Manual page 30

Parallel beam linear sensor
Table of Contents

Advertisement

Inspection for Loose Bottle Caps
1-1-3
Setting Measurement Unit
The following information is for Standard Sensors only.
The measurement unit can be set to linear output voltage (V) or
length (mm). In the following example, the unit is set to mm.
Set the measurement unit selector to mm. The Sensor is now
ready to display in millimeters.
Checking Measurement Width
Note If the displayed width is different from the measured width,
change the measurement width of the Amplifier. Otherwise the
linear output voltage will not be converted into length correctly.
→ Refer to Z4LB-S30V2 under 3-1 Selecting the Measure-
ment Unit (p. 24).
Display
Display
1 Press the TEACH and SET Keys simultaneously for 3 s.
The present measurement width will be displayed.
2 Press the SET Key.
The Sensor will return to RUN mode.
Section
1-1
5

Advertisement

Table of Contents
loading

Table of Contents