Self-peak Hold
5-6
Self-peak Hold
The maximum value while the measured value is equal to or
greater than the trigger level is displayed, output, and held.
discrimination outputs are controlled according to the displayed
value and output value.
The trigger level is a threshold value specifying the sampling pe-
riod of the measured value. When the measured value exceeds
the trigger level, the peak measured value during the sampling
period is held.
For the trigger level setting method, refer to 4-2-4 Display/Output
Value Hold Method (p. 42).
Note When timing input is ON during self-peak hold, no sampling is
performed. The discrimination outputs are not turned OFF when
the timing input turns ON.
Trigger level
Power ON or
hold reset input
Note To clear the held value and restart measurement, turn ON the
hold reset input.
Sampling
Display during
this period:
The measured value is output as a linear output.