H/W setting
Usually, this H/W setting is unnecessary.
Please perform this calibration only if a change at
the center of a stick should arise after prolonged use.
● Tap the [Calibration] button in the System
menu to call the setup screen shown below.
●Return to
System menu
How to Calibrate
1. Tap the "Calibration" button.
2. Choose the stick to calibrate right and left.
3. The stick is set at neutral and the [Set neutral]
button is tapped.
4. The stick is held at full right and full bottom
(diagonal). The [Set endpoint] button is
tapped.
5. The stick is held at full left and full top
(diagonal). The [Set endpoint] button is
tapped.
Stick mode selection and J1-J4 sticks calibration
Tapped
The stick is set at
neutral
Stick mode
Mode 1-4 can be chosen.
But, it isn't changed until data is reset.
To change the mode the stick ratchet
must be changed. Request that this
be done by Futaba Service. (Charged
modification)
*Please do not press the stick too firmly in any direction when
doing the calibration.
*Check after calibration to make sure that neutral is 0%, the
bottom right side is +100%, and the top left side is -100%.
56