5. Idle down setting
The idling speed can be lowered with one touch by
a switch without changing the throttle trim position.
Perform this setting with the Idle down function of the
Linkage menu. After activating the Idle down function
and selecting the switch, adjust the idle down speed. For
safety, the idle down function acts only when the throttle
stick is slow side.
*While the Throttle cut function is in operation, the Idle down
function does not work.
6. AFR (D/R)
AFR function is used to adjust the throw and operation
curve of the stick, lever, and switch functions for each
flight condition. This is normally used after End point
has defined the maximum throw directions.
7. Airbrake
This function is used when an air brake is necessary
when taking off or diving, etc.
The preset elevators and flaps (camber flap, brake flap)
offset amount can be activated by a switch.
The offset amount of the aileron, elevator, and flap
servos can be adjusted as needed. Also the speed of the
aileron, elevator, and flap servos can be adjusted. (In
side/Out side) A delay can be set for each condition,
and a cut switch which will turn OFF the delay can be
chosen. Trim amounts can be fine-tuned by setting a VR.
You can also set the auto mode, which will link Airbrake
to a stick, switch, or dial. A separate stick switch or dial
can also be set as the ON/OFF switch.
8. Addition of flight conditions
The Condition select function automatically allocates
the Condition 1 for each model. Condition 1 is the
default condition and is the only one active when a new
model type is defined.
If you want to add flight conditions, please refer to a
description of the Condition select function.
*The Condition 1 is always on, and remains on until other
conditions are activated by switches.
*When a new condition is added, the model data of the
Condition 1 is automatically copied to the new condition.
*You can set the model data of new condition in the switch
ON state. However, if the group mode (Gr) was selected in
advance, the same data will be input at all the conditions.
Select the single mode (Sngl) and adjust only the condition
you want to change. For Group/Single mode switching, refer
to the description at the back of this manual.
*The Condition delay can be programmed for each channel.
The Condition delay is used to change the servo throw
smoothly when switching conditions.