Verifying System Information Backup Or Restore - Fujitsu PRIMERGY RX2540 M6 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2540 M6:
Table of Contents

Advertisement

Basic software procedures
▶ Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
CAUTION
If the process is interrupted, the iRMC may be permanently
corrupted.
Do not interrupt the iRMC upgrade process after it has started.
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
▶ Shut down the server by pressing the power On/Off button.
▶ Disconnect the server from the mains to exit the iRMC recovery state.
5.3.2

Verifying system information backup or restore

To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored
from the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the
new system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL), see
Event Log (SEL)" on page
When using the Infrastructure Manager, please refer to the following
manuals about backup and restore function of system information.
See manual "FUJITSU Software Infrastructure Manager Vx.x.x User's
Guide", section "2.10 Backup/Restore Hardware Settings", available at:
https://ts.fujitsu.com/support/
For Japan:
See manual "FUJITSU Software Infrastructure Manager Vx.x.x 解説書",
section "2.10 ハードウェア設定バックアップ/リストア機能", available at:
https://www.fujitsu.com/jp/products/software/infrastructure-software/
infrastructure-software/serverviewism/technical/
94
"Viewing and clearing the System
101.
Upgrade and Maintenance Manual
RX2540 M6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents