P2 - 10
DI1
Digital Input Terminal 1 (DI1)
Default: 101
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 147
Settings:
This parameter is used to determine the function and status of DI1.
•
A: DI Function Settings: For the setting value of P2- 10 ~ P2-17, please refer to Table 7.A.
•
B: DI Enabled Status Settings:
0: Normally closed (contact b)
1: Normally open (contact a)
Please re-start the servo drive after parameters have been changed.
P2 - 11
DI2
Digital Input Terminal 2 (DI2)
Default: 104
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 12
DI3
Digital Input Terminal 3 (DI3)
Default: 116
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
Revision January 2009
Chapter 7 Servo Parameters|ASDA-AB Series
A
B
not used
Communication Addr.: 020AH
Related Section:
Table 7.A
Communication Addr.: 020BH
Related Section:
Table 7.A
Communication Addr.: 020CH
Related Section:
Table 7.A
7-55