Chapter 5 Trial Run and Tuning Procedure|ASDA-AB Series
Table 5.C P2-31 Value "B" Setting in AutoMode (PDFF) and the Speed Loop Responsiveness.
P2-31 value "B"
Speed Loop Responsiveness
0
1
2
3
4
5
6
7
5-20
P2-31 value "B"
20HZ
30 HZ
40 HZ
50 HZ
60 HZ
70 Hz
80Hz
100Hz
Speed Loop Responsiveness
8
9
A
B
C
D
E
F
120Hz
140HZ
160HZ
180HZ
200Hz
220Hz
260Hz
300HZ
Revision January 2009