Chapter 7 Servo Parameters|ASDA-AB Series
P2 - 61
GR5
Electronic Gear Ratio (3rd Numerator) (N3)
Default: 1
Applicable Control Mode: Pt, Pr
Unit: pulse
Range: 1 ~ 32767
Settings:
Please refer to P2-60.
P2 - 62
GR6
Electronic Gear Ratio (4th Numerator) (N4)
Default: 1
Applicable Control Mode: Pt, Pr
Unit: pulse
Range: 1 ~ 32767
Settings:
Please refer to P2-60.
7-72
Communication Addr.: 023DH
Related Section: N/A
Communication Addr.: 023EH
Related Section: N/A
Revision January 2009