P2 - 31
AUT1
Auto Mode Responsiveness Level
Default: 44
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ FF
Settings:
This parameter allows the users to set the responsiveness level setting of auto-tuning mode.
Users can control the responsiveness according to application condition. When the setting value
is higher, the responsiveness is higher.
A: No function
B: Responsiveness level of auto-tuning mode
0 ~ FF: 0 indicates the lowest setting and F indicates the highest setting (total 16 settings
available).
NOTE
1) This parameter is activated by P2-32.
2) Please refer to Section 5.6 for the tuning procedure and the related settings.
Revision January 2009
A
B
not used
Chapter 7 Servo Parameters|ASDA-AB Series
Communication Addr.: 021FH
Related Section:
Section 5.6, Section 6.3.6
7-61