P1 - 20
PO3L
3rd Position Command for Pulse
Default: 0
Applicable Control Mode: Pr
Unit: pulse
Range: +/-max. cnt/rev
Settings:
This parameter is used to set rotation pulse number of internal position 3.
Stroke3 = PO3H × (cnt/rev) + PO3L
P1 - 21
PO4H
4th Position Command for Rotation
Default: 0
Applicable Control Mode: Pr
Unit: rev
Range: -30000 ~ +30000
Settings:
This parameter is used to set rotation cycle number of internal position 4.
P1 - 22
PO4L
4th Position Command for Pulse
Default: 0
Applicable Control Mode: Pr
Unit: pulse
Range: +/-max. cnt/rev
Settings:
This parameter is used to set rotation pulse number of internal position 4.
Stroke4 = PO4H × (cnt/rev) + PO4L
P1 - 23
PO5H
5th Position Command for Rotation
Default: 0
Applicable Control Mode: Pr
Unit: rev
Range: -30000 ~ +30000
Settings:
This parameter is used to set rotation cycle number of internal position 5.
Revision January 2009
Chapter 7 Servo Parameters|ASDA-AB Series
Communication Addr.: 0114H
Related Section:
Section 6.2.2
Communication Addr.: 0115H
Related Section:
Section 6.2.2
Communication Addr.: 0116H
Related Section:
Section 6.2.2
Communication Addr.: 0117H
Related Section:
Section 6.2.2
7-35