Delta Electronics AC Servo Drive ASDA-AB User Manual page 207

Asda-ab series advanced ac servo drive for general purpose applocations
Table of Contents

Advertisement

Chapter 7 Servo Parameters|ASDA-AB Series
P2 - 21
DO4
Digital Output Terminal 4 (DO4)
Default: 105
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
P2 - 22
DO5
Digital Output Terminal 5 (DO5)
Default: 7
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
P2 - 23
NCF
Notch Filter (Resonance Suppression)
Default: 1000
Applicable Control Mode: ALL
Unit: Hz
Range: 50 ~ 1000
Settings:
This parameter is used to set resonance frequency of mechanical system. It can be used to
suppress the resonance of mechanical system. If P2-24 is set to 0, this parameter is disabled.
Notch Filter Attenuation Rate
P2 - 24
DPH
(Resonance Suppression)
Default: 0
Applicable Control Mode: ALL
Unit: dB
Range: 0 ~ 32
Settings: 0: Disabled
7-58
Communication Addr.: 0215H
Related Section:
Table 7.B
Communication Addr.: 0216H
Related Section:
Table 7.B
Communication Addr.: 0217H
Related Section:
Section 6.3.7
Communication Addr.: 0218H
Related Section:
Section 6.3.7