Chapter 3 Connections and Wiring|ASDA-AB Series
DI
Signal
Code
Reference "Home"
ORGP
24
sensor
Reverse operation
torque limit (torque limit
TLLM
25
function is valid only
when P1-02 is enabled)
Forward operation
torque limit (torque limit
TRLM
26
function is valid only
when P1-02 is enabled)
SHOM
27 Move to "Home"
Feed step selection input
INDEX0
28
0 (bit 0)
Feed step selection input
INDEX1
29
1 (bit 1)
Feed step selection input
INDEX2
30
2 (bit 2)
Feed step selection input
INDEX3
31
3 (bit 3)
Feed step selection input
INDEX4
32
4 (bit 4)
MD0
33 Feed step mode input 0
MD1
34 Feed step mode input 1
Manually continuous
MDP0
35
operation
Manually single step
MDP1
36
operation
JOGU
37 Forward JOG input
JOGD
38 Reverse JOG input
Step up input (available
STEPU
39
in Pr mode only)
Step down input
STEPD
40
(available in Pr mode
only)
Step back input.
STEPB
41
(available in internal auto
running mode only)
AUTOR
42 Auto run input
Electronic gear ratio
GNUM0
43
(Numerator) selection 0
[see P2-60~P2-62]
Electronic gear ratio
GNUM1
44
(Numerator) selection 1
[see P2-60~P2-62]
INHP
45 Pulse inhibit input
3-24