Chapter 7 Servo Parameters|ASDA-AB Series
P1 - 03
AOUT
Pulse Output Polarity Setting
Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 1
Settings:
A: Monitor analog output polarity
A=0: MON1(+), MON2(+)
A=1: MON1(+), MON2(-)
A=2: MON1(-), MON2(+)
A=3: MON1(-), MON2(-)
P1 - 04
MON1
Analog Monitor Output Proportion 1 (CH1)
Default: 100
Applicable Control Mode: ALL
Unit: % (full scale)
Range: 0 ~ 100
P1 - 05
MON2
Analog Monitor Output Proportion 2 (CH2)
Default: 100
Applicable Control Mode: ALL
Unit: % (full scale)
Range: 0 ~ 100
Accel / Decel Smooth Constant of Analog Speed
P1 - 06
SFLT
Command (Low-pass Filter)
Default: 0
Applicable Control Mode: S
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
7-30
A
B
not used
B: Position pulse output polarity
B=0: Forward output
B=1: Reverse output
Communication Addr.: 0103H
Related Section:
Section 3.3.3
Communication Addr.: 0104H
Related Section:
Section 6.4.4
Communication Addr.: 0105H
Related Section:
Section 6.4.4
Communication Addr.: 0106H
Related Section:
Section 6.3.3