Section 7:
This section discusses using the Attached Devices | Port pages to change IO-Link device parameters.
Note: Optionally, you can use traditional methods such as: PLC interfaces or HMI/SCADAs, depending
on your protocol to configure the IO-Link devices.
7.1
Port Pages Overview
You can use the Attached Devices | Port page for a port to review and easily edit the IO-Link device
configuration or view Process Data.
Figure 47: Attached Devices | Port
The Port page provides two IO-Link device configuration methods:
Configuring IO-Link Devices
Configuring IO-Link Devices
IO-Link Device Port table (GUI), which depends on the appropriate IODD file loaded
•
from the IO-Link device manufacturer onto the IOLM. To use the IO-Link Device Port
table for configuring IO-Link devices, refer to the following subsections:
Editing Parameters - IO-Link Device - Port Table on Page 127
o
Resetting IO-Link Device Parameters to Factory Defaults on Page 128
o
•
IO-Link Device ISDU Interface - Port, which can be used with or without IODD files
loaded. Refer to the following information to use the IO-Link Device ISDU Interface -
Port method:
The IO-Link Device Operator Manual from the device manufacturer is needed to use
o
the IO-Link Device ISDU Interface since the ISDU block index and ISDU sub-index
numbers are required.
Editing Parameters - IO-Link Device ISDU Interface - Port on Page 130
o