Port Models - Emerson RSTi-OM User Manual

Fieldbus module with profinet io and modbus/tcp
Hide thumbs Also See for RSTi-OM:
Table of Contents

Advertisement

RSTi-OM User Manual
GFK-3212A
11.2.1

Port Models

IO-Link Port 5
Multiple
Port PDI
4999 (Base 0)
Data
5000 (Base 1)
Block(s)
Port
Specific
5000 (Base 0)
PDI Data
5001 (Base 1)
Block
Multiple
Port PDO
5049 (Base 0)
Data
5050 (Base 1)
Block(s)
Port
Specific
5050 (Base 0)
PDO Data
5051 (Base 1)
Block
Receive
5100 (Base 0)
ISDU
5101 (Base 1)
Response
Transmit
5300 (Base 0)
ISDU
5301 (Base 1)
Request
Port Information Block (Continuous Block)
Vendor
5500 (Base 0)
Name
5501 (Base 1)
Vendor
5532 (Base 0)
Text
5533 (Base 1)
Product
5564 (Base 0)
Name
5565 (Base 1)
5596 (Base 0)
Product Id
5597 (Base 1)
Product
5628 (Base 0)
Text
5629 (Base 1)
Serial
5660 (Base 0)
Number
5661 (Base 1)
Hardware
5668 (Base 0)
Revision
5669 (Base 1)
Firmware
5700 (Base 0)
Revision
5701 (Base 1)
Device PDI
5732 (Base 0)
Length
5733 (Base 1)
Device
5733 (Base 0)
PDO
5734 (Base 1)
Length
Modbus/TCP Interface
IO-Link Port 6
IO-Link Port 7
5999 (Base 0)
6999 (Base 0)
6000 (Base 1)
7000 (Base 1)
6000 (Base 0)
7000 (Base 0)
6001 (Base 1)
7001 (Base 1)
6049 (Base 0)
7049 (Base 0)
6050 (Base 1)
7050 (Base 1)
6050 (Base 0)
7050 (Base 0)
6051 (Base 1)
7051 (Base 1)
6100 (Base 0)
7100 (Base 0)
6101 (Base 1)
7101 (Base 1)
6300 (Base 0)
7300 (Base 0)
6301 (Base 1)
7301 (Base 1)
6500 (Base 0)
7500 (Base 0)
6501 (Base 1)
7501 (Base 1)
6532 (Base 0)
7532 (Base 0)
6533 (Base 1)
7533 (Base 1)
6564 (Base 0)
7564 (Base 0)
6565 (Base 1)
7565 (Base 1)
6596 (Base 0)
7596 (Base 0)
6597 (Base 1)
7597 (Base 1)
6628 (Base 0)
7628 (Base 0)
6629 (Base 1)
7629 (Base 1)
6660 (Base 0)
7660 (Base 0)
6661 (Base 1)
7661 (Base 1)
6668 (Base 0)
7668 (Base 0)
6669 (Base 1)
7669 (Base 1)
6700 (Base 0)
7700 (Base 0)
6701 (Base 1)
7701 (Base 1)
6732 (Base 0)
7732 (Base 0)
6733 (Base 1)
7733 (Base 1)
6733 (Base 0)
7733 (Base 0)
6734 (Base 1)
7734 (Base 1)
IO-Link Port 8
Access
7999 (Base 0)
Read-
8000 (Base 1)
Only
8000 (Base 0)
Read-
8001 (Base 1)
Only
8049 (Base 0)
Read/
8050 (Base 1)
Write
8050 (Base 0)
Read/
8051 (Base 1)
Write
8100 (Base 0)
Read-
8101 (Base 1)
Only
8300 (Base 0)
Write-
8301 (Base 1)
Only
8500 (Base 0)
Read-
8501 (Base 1)
Only
8532 (Base 0)
Read-
8533 (Base 1)
Only
8564 (Base 0)
Read-
8565 (Base 1)
Only
8596 (Base 0)
Read-
8597 (Base 1)
Only
8628 (Base 0)
Read-
8629 (Base 1)
Only
8660 (Base 0)
Read-
8661 (Base 1)
Only
8668 (Base 0)
Read-
8669 (Base 1)
Only
8700 (Base 0)
Read-
8701 (Base 1)
Only
8732 (Base 0)
Read-
8733 (Base 1)
Only
8733 (Base 0)
Read-
8734 (Base 1)
Only
Section 11
Jun 2021
Length
Configurable
per port (s)
Configurable
per port
Configurable
per port(s)
Configurable
per port
4 to 125
Words
4 to 123
Words
232 Words
64 Chars
32 Words
64 Chars
32 Words
64 Chars
32 Words
64 Chars
32 Words
64 Chars
32 Words
16 Chars
8 Words
64 Chars
32 Words
64 Chars
32 Words
1 Word
1 Word
112

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omiolm001

Table of Contents