Aligning The Feed-Dog Carrier Together With The Stitch Regulator Gear - Dürkopp Adler M-TYPE H867 Service Manual

Table of Contents

Advertisement

9.1.3 Aligning the feed-dog carrier together with the stitch regulator
gear
If moving the feed-dog carrier does not suffice, the feed-dog carrier must
be aligned together with the stitch regulator gear.
Cover
• Tilt the upper section backwards
Figure 24: Moving the feed-dog carrier cross-line to the sewing direction
Setting steps
Moving the feed-dog carrier cross-line to the sewing direction
1. Remove the tension spring (8) from the mounting bracket.
2. Loosen the connection to the tie rod using the screws (1).
3. Loosen the rear assembly frame screw (6).
4. Loosen the setscrews for the adjusting rings (2).
5. Move the feed-dog carrier cross-line to the sewing direction such that
6. Push the adjusting rings (2) toward each other as far as they will go.
7. Tighten the setscrews for the adjusting rings (2).
34
(
Section 4.4.1 Access to the machine bottom section, page 10)
(1) - Tie rod connecting screws
(2) - Adjusting rings
(3) - Sliding shaft
(4) - Assembly frame
the feed-dog is exactly in the center of the throat plate cut-out.
Important: Make sure that the sliding shaft (3) is tightened by the
clamping rings.
Setting the feed-dog
(5) - Plates
(6) - Assembly frame screw
(7) - Screw
(8) - Tension spring
Service manual H867 Version 00.0 - 08/2013

Advertisement

Table of Contents
loading

Table of Contents