Installation
4.2 Electrical Installation
Default setting 8: "MOP with Basic Safety"
DO 0: p0730, DO 1: p0731
Motorized potentiometer, setpoint after the ramp-function generator r1050
Speed setpoint (main setpoint): p1070[0] = 1050
Default setting 9: "Standard I/O with MOP"
DO 0: p0730, DO 1: p0731
Motorized potentiometer, setpoint after the ramp-function generator r1050
Speed setpoint (main setpoint): p1070[0] = 1050
62
DI 0: r0722.0, ..., DI 5: r0722.5
DI 0: r0722.0, ..., DI 3: r0722.3
Converter with the control units CU240D-2
Operating Instructions, 10/2020, FW V4.7 SP13, A5E34262100B AH