Get Reset Info Of Min- / Max Tempearture (03H, A3Ffh); Get Stroke Length Distribution (03H, A400H) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

C.6.15
G
R
ET
This service returns the date of last reset of "Minimum Temperature" and "Maximum Temperature"
values.
Request table – Get Reset Info of Min- / Max Temperature:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Starting Address / Service ID – Get Reset Info of Min- / Max Temperature
3
4
Quantity of Registers
5
6
CRC
7
Response table – Get Reset Info of Min- / Max Temperature:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
Date of last value reset of Min- / Max Temperature
3
Coding: BCD coded
4
Format: YYMMDD
5
000000h = value was not written at value reset
Time stamp of last value reset of Min- / Max Temperature
6
Operating time at last value reset.
7
Resolution: 1min per LSB
8
Range: 0 to 16777215 min
CRC
9
10
C.6.16
G
S
ET
One stroke is defined as the movement between two standstills. This service returns the Stroke
Length Distribution. The length of stroke decides which of the 6 different counters is incremented.
If one counter reaches the maximum value of 65535 dec (=FFFFhex), this counter is fixed at this
maximum value. In this case an information event is stored. Please see chapter C.5.3 for further
information.
Request table – Get Stroke Length Distribution:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Starting Address / Service ID – Get Stroke Length Distribution
3
4
Quantity of Registers
5
6
CRC
7
F037 300 069 (2015.09.02)
I
M
- / M
ESET
NFO OF
IN
L
D
TROKE
ENGTH
ISTRIBUTION
T
(03
AX
EMPEARTURE
H
(03
, A400
)
H
H
70
, A3FF
)
H
Value
A2h
03h
A3h
FFh
00h
03h
XXh
XXh
Value
A2h
03h
06h
YYh
MMh
DDh
XXh
XXh
XXh
XXh
XXh
Value
A2h
03h
A4h
00h
00h
06h
XXh
XXh

Hide quick links: