Read Customer Number (01H) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

Response CIMS
MASTER
->
Byte Contents
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Vendor Name
8
Object Length
9
Payload
Coding:
ASCII string
...
Length:
Variable, the byte 8 contains the used length LL
minimum length: 3 byte
8+LL
maximum length: 23 byte
Example:
'Bosch Rexroth B.V.'
9+LL CRC
10+LL
C.4.3
R
EAD
This service reads the Customer Number. This number used by end customer to order the sensor
at Bosch Rexroth.
Request table – Read Customer Number:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Read Device ID code - Specific Identification Object (Individual Access)
4
Object ID - Customer Number
5
CRC
6
Response table – Read Customer Number:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Customer Number
8
Object Length
9
Payload
Coding:
ASCII string
...
Length:
Variable, the byte 8 contains the used length LL
minimum length: 3 byte
maximum length: 16 byte
8+LL
Format:
'R XXX XXX XXX'
Example:
'R 905 027 688'
9+LL CRC
10+LL
F037 300 069 (2015.09.02)
C
N
(01
USTOMER
UMBER
)
H
43
Value
83h
00h
00h
01h
00h
LLh
XXh
...
XXh
XXh
XXh
Value
A2h
2Bh
0Eh
04h
01h
XXh
XXh
Value
A2h
2Bh
0Eh
83h
00h
00h
01h
01h
LLh
XXh
...
XXh
XXh
XXh

Hide quick links:

Advertisement

Table of Contents
loading