C.4.20
R
EAD
Read the build archive consistency of bootloader firmware.
Request table – Read Bootloader Build Date:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Read Device ID code - Specific Identification Object (Individual Access)
4
Object ID - Bootloader Build Date
5
CRC
6
Response table – Read Bootloader Build Date:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Bootloader Build Date
8
Object Length
Payload
9
Coding:
ASCII string
Length:
Variable, the byte 8 contains the used length LL
...
maximum length: 20 byte
8+LL
Example:
`2015/05/09 15:54:36`
9+LL CRC
10+LL
C.5
S
ENSOR
To use the Fault Management services the MODBUS function Read Holding Registers 03h is used
as described in [2]. In contrast to this specification, the Starting Address is not used as a physical
address, but more as a Service ID. The CIMS Sensor supports only access to one Service ID
(Address) at each request.
C.5.1
P
OSSIBLE
Negative response table – Sensor Fault Management
Error CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Error Function Code (Function Code + 80h)
Exception Code
2
0x02 - Illegal Data Address - If Service ID not supported.
0x04 - Slave Device Failure - If the syntax of the request is wrong.
3
CRC
4
F037 300 069 (2015.09.02)
B
B
D
OOTLOADER
UILD
F
M
AULT
ANAGEMENT
E
M
RROR
ESSAGES
(B7
)
ATE
H
55
Value
A2h
2Bh
0Eh
04h
B7h
XXh
XXh
Value
A2h
2Bh
0Eh
83h
00h
00h
01h
B7h
LLh
XXh
...
XXh
XXh
XXh
Value
A2h
FC+80h
XXh
XXh
XXh

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents