Get Maximum Deceleration (03H, A220H) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

C.6.11
G
M
ET
This service returns the Maximum Deceleration, environmental information and the operation time
when this maximum Deceleration happened.
Request table – Get Maximum Deceleration:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Starting Address / Service ID – Get Maximum Deceleration
3
4
Quantity of Registers
5
6
CRC
7
Response table – Get Maximum Deceleration:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
Direction
Direction of piston rod movement at the moment when maximum deceleration happened.
3
00h = extending
01h = retracting
Maximum Deceleration
4
2
Resolution: 0.001m/s
per LSB (unsigned value)
5
2
Range: 0 to 32.767m/s
Position status
Status of CIMSmart internal position at the moment when maximum deceleration happened.
6
00h = internal position was not referenced since last power up
01h = internal position was referenced since last power up
Position
7
CIMSmart internal position at the moment when the maximum deceleration happened.
8
Resolution: 0.1mm per LSB (signed value)
9
Range: -419.4304m to 419.4303m
10
Temperature
CIMSmart internal temperature at the moment when the maximum deceleration happened.
11
Resolution: 1 ºC per LSB (signed value)
Range: -128 to 127 ºC
Time Stamp
12
Operating time at the moment when the maximum deceleration happened.
13
Resolution: 1min per LSB
14
Range: 0 to 16777215min (~279620 hours ~11650 days ~31years)
CRC
15
16
F037 300 069 (2015.09.02)
D
AXIMUM
ECELERATION
(03
, A220
)
H
H
67
Value
A2h
03h
A2h
20h
00h
06h
XXh
XXh
Value
A2h
03h
0Ch
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents