4.1. M
CIMS
OUNTING
The CIMSmart can be mounted and configured in most of the cases without opening the housing.
The assembly steps are detailed in 4 phases:
-
Phase 1: Configuration of the output connection position,
-
Phase 2: Check / change the cable outlet,
-
Phase 3: Mount new cable outlet,
-
Phase 4: Installation onto the cylinder.
The configuration phases (Phases 1, 2 and 3) should be carried out on a clean and stable surface.
4.1.1. P
1: C
HASE
Before starting installation onto the cylinder, make sure the connection output is oriented correctly
with respect to the cylinder. Note that the orientation mark on CIMSmart (see Figure 3) should
always point to the rod side of the cylinder. If the connector is not pointing in the desired direction,
follow the instructions below. Do not mount the CIMS with the orientation mark in the wrong
direction as this might lead to damage or malfunction of the CIMS.
At delivery from the factory, the connection output is oriented as depicted in Figure 2 and Figure 3.
If this is not the desirable configuration, the connection output can be changed (in steps of 90)
according the instructions below. If the connection output is already in the desired orientation,
continue with Phase 2.
Figure 2: Top view CIMSmart on cylinder
Longitudinal
axis cylinder
Figure 3: View along longitudinal axis of cylinder, zoom of CIMSmart with its orientation mark.
F037 300 069 (2015.09.02)
ON CYLINDER
ONFIGURATION OF OUTPUT CONNECTION POSITION
Orientation mark on CIMSmart
pointing at rod side
14
The marking on the
CIMS (see zoom in
Figure 3) must be
aligned along the
longitudinal axis of the
cylinder. This results in
an installation situation
like the figure 2, with
the orientation mark
pointing at the rod end
side.