Adjustment Functions; Reset; Error Inquiry - Bosch BEA 150 Repair Instructions

Emissions analysis
Table of Contents

Advertisement

4.9

Adjustment functions

4.10 Reset

4.11

Error inquiry

i Make sure that the Service switch is
set to On before you open the Setting
functions menu.
For details on how to adjust the exhaust-
gas analyzer module and undertake
country-specific settings, please refer to
Section 4.5.1 (country-specific settings).
Return to the function menu by clicking
Back or by pressing keys Alt + B.
A reset must be performed when entries
have been modified in the Setting
functions
menu.
These
settings will only be stored in the
flashprom of the exhaust-gas analyzer
module after a reset.
Select Yes by clicking it or with the tab
key
. Confirm that you wish to perform
a reset with E or by double-clicking the
mouse.
The fault memory is deleted and the
exhaust-gas analyzer module is restarted.
i For approx. 15 s, the exhaust-gas
analyzer module has no connection to
the laptop or PC.
The following message therefore appears:
The measuring device reported hardware
failure!
The error code must be read!
After 15 s, restart the Service program
with E or by clicking OK.
Any current faults in the exhaust-gas
analyzer module are displayed in plain
text.
Confirm the readout of the fault memory
with E or by clicking OK. The fault
memory is deleted and the screen returns
to the Function menu.
i If a fault still remains in the exhaust-
gas analyzer, this will be displayed
again.