Read Serial Number (81H) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Manufacturing Date
8
Object Length
9
Payload
Coding:
ASCII string
...
Length:
10 bytes
Format:
YYYY + '-' + MM + '-' + DD
18
Example:
'2011-04-14'
19
CRC
20
C.4.6
R
EAD
The Serial Number is a number that uniquely identifies the product.
Request table – Read Serial Number:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Read Device ID code - Specific Identification Object (Individual Access)
4
Object ID - Serial Number
5
CRC
6
Response table – Read Serial Number:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Serial Number
8
Object Length
9
Payload
Coding:
ASCII string
...
Length:
Variable, the byte 8 contains the used length LL
minimum length: 3 byte
8+LL
maximum length: 16 byte
Example:
'259824/001'
9+LL CRC
10+LL
F037 300 069 (2015.09.02)
S
N
(81
)
ERIAL
UMBER
H
45
Value
A2h
2Bh
0Eh
83h
00h
00h
01h
80h
0Ah
XXh
...
XXh
XXh
XXh
Value
A2h
2Bh
0Eh
04h
81h
XXh
XXh
Value
A2h
2Bh
0Eh
83h
00h
00h
01h
81h
LLh
XXh
...
XXh
XXh
XXh

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents