Response table – Read Bootloader Build Archive Path:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Bootloader Build Archive Path
8
Object Length
Payload
9
Coding:
ASCII string
Length:
Variable, the byte 8 contains the used length LL
...
maximum length: 144 byte
8+LL
9+LL CRC
10+LL
C.4.19
R
EAD
Read the build archive consistency of bootloader firmware.
Request table – Read Bootloader Build Archive Consistency:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Read Device ID code - Specific Identification Object (Individual Access)
4
Object ID - Bootloader Build Archive Consistency
5
CRC
6
Response table – Read Bootloader Build Archive Consistency:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Encapsulated Interface Transport
2
MEI Type - Read Device Identification
3
Conformity Level - Extended Identification (Individual Access)
4
More Follows
5
Next Object Id
6
Number of Objects
7
Object ID - Bootloader Build Archive Consistency
8
Object Length
Payload
9
Coding:
ASCII string
Length:
Variable, the byte 8 contains the used length LL
...
maximum length: 24 byte
8+LL
9+LL CRC
10+LL
F037 300 069 (2015.09.02)
B
B
A
OOTLOADER
UILD
C
RCHIVE
ONSISTENCY
54
Value
A2h
2Bh
0Eh
83h
00h
00h
01h
B5h
LLh
XXh
...
XXh
XXh
XXh
(B6
)
H
Value
A2h
2Bh
0Eh
04h
B6h
XXh
XXh
Value
A2h
2Bh
0Eh
83h
00h
00h
01h
B6h
LLh
XXh
...
XXh
XXh
XXh