Get Reset Info Of Movement History (03H, A6Ffh) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

Response CIMS
MASTER
->
Byte Contents
1Fh = 00011111b = all units are kilometers
Travelled distance during last 365 operating days
5
Resolution: 1m or 1km per LSB
6
Range: 0 to 65535m or 1km to 65535km
Travelled distance during second last 365 operating days
7
Resolution: 1m or 1km per LSB
8
Range: 0 to 65535m or 1km to 65535km
Travelled distance during third last 365 operating days
9
Resolution: 1m or 1km per LSB
10
Range: 0 to 65535m or 1km to 65535km
Travelled distance during fourth last 365 operating days
11
Resolution: 1m or 1km per LSB
12
Range: 0 to 65535m or 1km to 65535km
Travelled distance during fifth last 365 operating days
13
Resolution: 1m or 1km per LSB
14
Range: 0 to 65535m or 1km to 65535km
CRC
15
16
C.6.21
G
R
ET
This service returns the date of last reset of "Movement History" values.
Request table – Get Reset Info of Movement History:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Starting Address / Service ID – Get Reset Info of Movement History
3
4
Quantity of Registers
5
6
CRC
7
Response table – Get Reset Info of Movement History:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
Date of last value reset of Movement History
3
Coding: BCD coded
4
Format: YYMMDD
5
000000h = value was not written at value reset
Time stamp of last value reset of Movement History
6
Operating time at last value reset.
7
Resolution: 1min per LSB
8
Range: 0 to 16777215 min
9
CRC
10
F037 300 069 (2015.09.02)
I
M
ESET
NFO OF
OVEMENT
H
(03
, A6FF
ISTORY
H
74
Value
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
)
H
Value
A2h
03h
A6h
FFh
00h
03h
XXh
XXh
Value
A2h
03h
04h
YYh
MMh
DDh
XXh
XXh
XXh
XXh
XXh

Hide quick links: