Get Reset Info Of Stroke Length Distribution (03H, A4Ffh) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

Response table – Get Maximum Deceleration:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
Stroke counter 1 for 0.01 to 0.1m
3
Resolution: 1 stroke per LSB
4
Range: 0 to 65535 strokes
Stroke counter 2 for 0.1 to 0.3m
5
Resolution: 1 stroke per LSB
6
Range: 0 to 65535 strokes
Stroke counter 3 for 0.3 to 1m
7
Resolution: 1 stroke per LSB
8
Range: 0 to 65535 strokes
Stroke counter 4 for 1 to 3m
9
Resolution: 1 stroke per LSB
10
Range: 0 to 65535 strokes
Stroke counter 5 for 3 to 10m
11
Resolution: 1 stroke per LSB
12
Range: 0. To 65535 strokes
Stroke counter 6 for 10 to inf. m
13
Resolution: 1 stroke per LSB
14
Range: 0 to 65535 strokes
CRC
15
16
C.6.17
G
R
ET
This service returns the date of last reset of "Stroke Length Distribution" values.
Request table – Get Reset Info of Stroke Length Distribution:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Starting Address / Service ID – Get Reset Info of Stroke Length Distribution
3
4
Quantity of Registers
5
6
CRC
7
Response table – Get Reset Info of Stroke Length Distribution:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
3
Reserved
Date of last value reset
4
Coding: BCD coded
5
Format: YYMMDD
6
000000h = value was not written at value reset
7
CRC
8
F037 300 069 (2015.09.02)
I
S
ESET
NFO OF
TROKE
L
D
ENGTH
ISTRIBUTION
71
Value
A2h
03h
0Ch
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
(03
, A4FF
)
H
H
Value
A2h
03h
A4h
FFh
00h
02h
XXh
XXh
Value
A2h
03h
04h
XXh
YYh
MMh
DDh
XXh
XXh

Hide quick links: