Get Maximum Temperature (03H, A310H) - Bosch Rexroth CIMSmart Instruction Manual

Table of Contents

Advertisement

Response table – Get Minimum Temperature:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
Reserved
3
Minimum Temperature
4
Minimum measure CIMSmart internal temperature since last reset of this value.
Resolution: 0.1°C per LSB (signed HEX coded)
5
Range: -128 °C to 127 °C
Time stamp of last value reset
6
Operating time at the time when the minimum temperature happened.
7
Resolution: 1min per LSB (HEX coded)
8
Range: 0 to 16777215 min
CRC
9
10
C.6.14
G
M
ET
The CIMSmart sensor measures indirectly the temperature in the sealing flange area. This service
returns the maximum temperature measured by the CIMSmart internal temperature sensor and the
Operating Time when this maximum temperature happened.
Request table – Get Maximum Temperature:
Request MASTER
CIMS
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Starting Address / Service ID – Get Maximum Temperature
3
4
Quantity of Registers
5
6
CRC
7
Response table – Get Maximum Temperature:
Response CIMS
MASTER
->
Byte Contents
0
Slave Address
1
Function Code - Read Holding Registers
2
Byte Count
Reserved
3
Maximum Temperature
4
Maximum measure CIMSmart internal temperature since last reset of this value.
Resolution: 0.1°C per LSB (signed HEX coded)
5
Range: -128 °C to 127 °C
Time stamp of last value reset
6
Operating time at the time when the maximum temperature happened.
7
Resolution: 1min per LSB (HEX coded)
8
Range: 0 to 16777215 min
CRC
9
10
F037 300 069 (2015.09.02)
T
AXIMUM
EMPERATURE
(03
, A310
)
H
H
69
Value
A2h
03h
06h
00h
XXh
XXh
XXh
XXh
XXh
XXh
XXh
Value
A2h
03h
A3h
10h
00h
03h
XXh
XXh
Value
A2h
03h
06h
00h
XXh
XXh
XXh
XXh
XXh
XXh
XXh

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents