Setting Data Links
5-2-3

Manual Setting Examples

SAMPLE1.CLK: Same Allocation to All Nodes
Data Link Area Structure
Device Information Settings
Data Link Tables
This section shows examples of manually creating data link tables on the
Controller Link Support Software. Sample files containing the data link tables
are provided on the installation disk for the Software.
C200HX
Node 1
Data Link Areas
Area 1
LR000
#1
LR010
#2
LR020
#3
LR030
#4
LR049
Area 2
D00000
#1
D00200
#2
D00300
#3
D00400
#4
D00599
Set exactly the same table for nodes 2, 3, and 4. To do this, the copy function
can be used to copy the data link table for node 1 to nodes 2, 3, and 4.
C200HX
C200HX
Node 2
Node 3
#1
#1
#2
#2
#3
#3
#4
#4
#1
#1
#2
#2
#3
#3
#4
#4
Section 5-2
C200HX
Node 4
#1
#2
#3
#4
#1
#2
#3
#4
125