Setting Data Links
Example:
IR/CIO Area
Example:
DM Area
C200HX/HG/HE or
CQM1H-series PLCs
0
to
235
C200HX/HG/HE or
CQM1H-series PLCs
DM000
DM000
to
DM5999
DM5999
DM24575
2. If the LR Area in a C200HX/HG/HE or CQM1H-series PLC is manually set
for a data link with a CVM1, CV-series, or CS/CJ-series PLC, the LR words
will be linked to CIO 1000 to CIO 1063 in the CVM1, CV-series or CS/CJ-
series PLC. CIO 1064 to CIO 1199 cannot be linked with C200HX/HG/HE
or CQM1H-series PLCs in this way.
C200HX/HG/HE or
CQM1H-series PLCs
CVM1, CS/CJ, or CV-series PLCs
LR00
1000
to
to
LR63
1063
1064
to
1199
CVM1, CS/CJ, or CV-series PLCs
0
to
Available for the data links
235
to
Not available for the data links
2555
CVM1, CS/CJ, or CV-series PLCs
to
Available for the data links
to
Not available for the data links
CIO words of CVM1, CS/CJ, or CV-series PLCs
= (LR words of C200HX/HG/HE or
CQM1H-series PLCs) + 1000
Cannot be directly linked
with C200HX/HG/HE words.
Section 5-2
151